| Vcc |
(mA) |
(ms) |
(Vo) |
(imp/r) |
output mode |
| 5Vdc |
≤10 |
or by wrens option |
≥0.7Vcc |
user may select
1,2,4 or 8 |
May output 1 or 2 inputse singnel and meter
mark rever |
| 9Vdc |
≤13 |
or by wrens option |
≥0.8Vcc |
user may select
1,2,4 or 8 |
May output 1 or 2 inputse singnel and meter
mark rever |
| 12Vdc |
≤15 |
or by wrens option |
≥0.8Vcc |
user may select
1,2,4 or 8 |
May output 1 or 2 inputse singnel and meter
mark rever |
| Name |
Type |
Accuracy |
Rated voltage(V) |
Rated current(A) |
Connection Mode |
| Three phase four wire active energy impulse
watt-hour meter |
DTM862 |
Class 2 |
3×380/220 |
3×1(2),3×1.5(6),
3×3(6) |
Input through current transformer |
| Three phase four wire active energy impulse
watt-hour meter |
DTM862 |
Class 2 |
3×380/220 |
3×5(20),3×10(40),
3×15(60),3×20(80),
3×30(100) |
Directly input |
| Three phase four wire active energy impulse
watt-hour meter |
DTM864 |
Class 1 |
3×380/220 |
3×1(2),3×1.5(6),
3×3(6) |
Input through current transformer |
| Three phase four wire active energy impulse
watt-hour meter |
DTM864 |
Class 1 |
3×100/57.5 |
3×1(2),3×1.5(6),
3×3(6) |
Input through current voltage transformer |
| Three phase three wire active energy impulse
watt-hour meter |
DSM862 |
Class 2 |
3×380 |
3×1(2),3×1.5(6),
3×3(6) |
Input through current transformer |
| Three phase three wire active energy impulse
watt-hour meter |
DSM862 |
Class 2 |
3×100 |
3×1(2),3×1.5(6),
3×3(6) |
Input through current voltage transformer |
| Three phase three wire active energy impulse
watt-hour meter |
DSM864 |
Class 1 |
3×380 |
3×1(2),3×1.5(6),
3×3(6) |
Input through current transformer |
| Three phase three wire active energy impulse
watt-hour meter |
DSM864 |
Class 1 |
3×100 |
3×1(2),3×1.5(6),
3×3(6) |
Input through current voltage transformer |
| Three phase four wire reactive energy impulse
watt-hour meter |
DXM862 |
Class 3 |
3×380 |
3×1(2),3×1.5(6),
3×3(6) |
Input through current transformer |
| Three phase four wire reactive energy impulse
watt-hour meter |
DXM862 |
Class 3 |
3×100 |
3×1(2),3×1.5(6),
3×3(6) |
Input through current voltage transformer |
| Three phase four wire reactive energy impulse
watt-hour meter |
DXM864 |
Class 2 |
3×380 |
3×1(2),3×1.5(6),
3×3(6) |
Input through current transformer |
| Three phase four wire reactive energy impulse
watt-hour meter |
DXM864 |
Class 2 |
3×100 |
3×1(2),3×1.5(6),
3×3(6) |
Input through current voltage transformer |
| Three phase three wire reactive energy
impulse watt-hour meter |
DXM865 |
Class 3 |
3×380 |
3×1(2),3×1.5(6),
3×3(6) |
Input through current transformer |
| Three phase three wire reactive energy
impulse watt-hour meter |
DXM865 |
Class 3 |
3×100 |
3×1(2),3×1.5(6),
3×3(6) |
Input through current voltage transformer |
| Three phase three wire reactive energy
impulse watt-hour meter |
DXM863 |
Class 2 |
3×380 |
3×1(2),3×1.5(6),
3×3(6) |
Input through current transformer |
| Three phase three wire reactive energy
impulse watt-hour meter |
DXM863 |
Class 2 |
3×100 |
3×1(2),3×1.5(6),
3×3(6) |
Input through current voltage transformer |