Model
DEM041BL three phase four wire electronic multi-rate DIN rail active
energy meter is a kind of three phase four wire two tariffs (tariff
conversion is controlled by timer outside or similar equipment)
active energy meter, the meter completely accord with relevant
technical requirements of class 1 three phase active energy meter
stipulated in international standard IEC 62053-21. It can accurately
and directly measure 50Hz or 60Hz active energy consumption from
three phase four wire AC electricity net. This meter has seven
digits LCD monitors shows various consumption data and information.
And there are far infrared and RS485 communication module in it. It
is use for setting and reading the meter. Contact with all kind of
AMR system conveniently. It has following features: Good
reliability, small volume, light weight, specious nice appearance,
convenient installation, etc. This meter has already got the patent
certificate from Chinese national Intellectual Property Office at
present. Patent certificate NO. ZL 2006 3 0107349.1, any other
country patent certificate are in assessing.
|
| |
|
 |
|
|
DEM041BL
kilowatt-hour meter
Function and features: |
|
-DEM041BL
kilowatt-hour meter -35mm
standard DIN rail installation, complying with standard DIN EN50022.
Or front
board setting (mounting holes center
distance 63 mm), users can choose any one by
themselves.
-DEM041BL
kilowatt-hour meter-Ten
pole width (Modulus 12.5mm), complying with standard JB/T7121-1993.
-DEM041BL
kilowatt-hour meter-Have
three tariffs, may select 12 daily period of times. You can set the
date arbitrary which
can automatically read the
meter every month. May select single tariff function in
weekend.
(Please specified when ordering)
-DEM041BL
kilowatt-hour meter-There
is a clock and Maintenance-free backup lithium batteries in it.
Battery capacity
detection and display all the time.It can keep the
electricity data for 12 months. The data
can be kept forever after power cut off.
-DEM041BL
kilowatt-hour meter-May
select cycle display (default) or push the button itemized display,
we can set the cycle
display, it can display 14 data
at most. Can select the data which displayed. The decimal
median which displayed can choose set one or two.
-DEM041BL
kilowatt-hour meter-Use memory that is not lost easily, the data can be kept
forever after power cut off.
-DEM041BL
kilowatt-hour meter-There are far infrared and a
port of RS485 communication data. It is use for setting
and
reading the meter. Set and operation
have password protection, communication protelot
complying
with standard DL/T645-1997.
-DEM041BL
kilowatt-hour meter-Nine
LED instructions respectively power state, signal of power impulse,
the direction of
the trend of load current, the state
rates just now and the data communications state.
-DEM041BL
kilowatt-hour meter-Single
direction three components measure three phase four wire active
power
consumption. It is nothing with direction
of
the trend of load current. Complying with
standard IEC 62053-21.
-DEM041BL
kilowatt-hour meter-Standard
configuration type S connection (Inlet from bottom, outlet from top)
for direct
connect to use, we can also choose
another type of connection, and use CT (Product
Configuration code is BN) and PT & CT (Product
Configuration code
is BP) for operation.
-DEM041BL
kilowatt-hour meter-Standard
configuration extended terminals cover, may select short terminals
cover, in
order to protect to use electricity
safely. (Product Configuration code is BM). |
|
DEM041BL
kilowatt-hour meter
Technical parameters: |
| Model |
Accuracy |
Reference voltage(V) |
Current
specifications
(A) |
Starting Current |
Insulation
Performance |
| DEM041BL |
class1 |
3 x 127/220
3 x 230/400
|
5(30)
10(60)
20(100) |
0.02
0.04
0.08 |
AC voltage 4kV for 1
minute,1.2/50us waveform impulse
voltage 6kV |
|
|
DEM041BL
kilowatt-hour meter
Outer and mount dimension: |
|
|
|
DEM041BL
kilowatt-hour meter
Wiring diagram(Type S) |
|
|
|
|
|
|
|
|
| |
|
Our Products |
|
|
Watt hour meter,
watt hour meters,
kilowatt hour meter,
kilowatt hour meters,
kilowatt-hour meter,
kilowatt-hour meters,
kwhmeter,
kwh meters,
electricity meter,
electricity meters,
electric meter,
electric meters,
electronic meter,
electronic meters,
electrical meter,
electrical meters,
KwhMeters,
kwh-meter,
Electric Energy Meter,
billing meter,
Static Watt Hour Meter,
mechanical kwh meters,
watthour power meter,
AC Kilowatt-Hour Meter,
mechanical kwh meter,
mechanical energy meter,
single phase mechanical KWH meter,
three phase mechanical KWH meter,
electro-mechanical kWh meter,
prepaid KWH meter,
prepayment meter,
electricity meters with prepaid chip cards,
multi meter,
Single phase electronic prepayment watt-hour meter,
china meter, top-quality electricity meters,
DIN rail kWh meters,
din rail watt-hour meter,
DIN Rail Energy Meter,
Din-rail Electronic Watt-hour Meter,
DIN Rail Mounted kWh Meters,
single phase DIN rail watt-hour meter,
single phase DIN rail kWh meters,
three phase din rail kWh meter,
three Phase electronic kWh electricity meters,
Single Phase electronic kWh electricity meters,
Din Mount single-phase class 1 kilowatt hour meter,
Din Mount three-phase class 1 kilowatt hour meter,
Din Rail mount 1 Module single phase Kilowatt Hour Meter |
|
|
|